Honeywell Q539F Manual de usuario

Busca en linea o descarga Manual de usuario para Panel De Control Honeywell Q539F. Honeywell Q539F User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 12
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Honeywell
THERMOSTAT
SUBBASES
THE Q539 SUBBASES PROVIDE COOLING ANTICI
PATORS. WIRING TERMINALS. AND MOUNTING
BASES FOR T87F THERMOSTATS. MOST ALSO
PROVIDE SYSTEM AND FAN SWITCHING FOR
HEATING. COOLING. AND HEATING-COOLING
THERMOSTATS.
Screw terminals for electrical connections are letter-
coded for quick, accurate installation.
Shunt type carbon heater provides cooling anticipa
tion for close temperature control.
Guide posts assure mounting and leveling necessary
to maintain thermostat calibration.
Fan and system switch levers (available on most
models) located at top edge for convenient control.
Indicator LED available on most models.
Mount directly on wall or on standard outlet box with
accessory wallplate. i
Q539P with indicator LED for oil primary systems
(HEAT-only).
Q539A,B,C,F,
D.T.
Rev. 10-89
Form Number 60-2246—4
© Honeywell Inc. 1989
Vista de pagina 0
1 2 3 4 5 6 ... 11 12

Indice de contenidos

Pagina 1 - Honeywell

HoneywellTHERMOSTATSUBBASESTHE Q539 SUBBASES PROVIDE COOLING ANTICIPATORS. WIRING TERMINALS. AND MOUNTING BASES FOR T87F THERMOSTATS. MO

Pagina 2 - ORDERING INFORMATION

OPERATIONThe Q539 Subbase provides cooling anticipation, wiring terminals, mounting base, and system and fan switching for the T87F Thermostat

Pagina 3

NOTES—1160-2246—4

Pagina 4 - INSTALLATION

Honeywell Inc.1885 Douglas Drive N.International Sales Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, Fran

Pagina 5

SPECIFICATIONSIMPORTANTTHE SPECIFICATIONS GIVEN IN THIS PUBLICATION DO NOT INCLUDE NORMAL MANUFACTURING TOLERANCES. THEREFORE, THIS UNI

Pagina 6 - <i) I

TABLE 1—MODEL SPECIFICATIONSMODEL AND DESCRIPTIONSYSTEM SWITCHING (dpst and dp3t)FANSWITCHING(spdt)SUBBASE TERMINALS WIRINGDIAGRAMR W Y BGo X p zRc R»

Pagina 7 - 7 60-2246-4

Table 1 (continued)MODEL AND DESCRIPTIONSYSTEM SWITCHING (dpst and dp3t)FANSWITCHING(spdt)SUBBASE TERMINALSWIRINGDIAGRAMR W Y B GO X p zRc R-Q539J1022

Pagina 8

they can be pushed back into the wall later.2. In new installations, run wiring (if necessary) to the subbase location.3. Connect the wires to

Pagina 9 - CHECKOUT

Q539An'87FHEATING DAMPER MOTOR (IF USED)WITCH_C “<i) IA ^T-0^1COOLING DAMPER MOTOR (IF USED)“1“AA X TERMINAL IS USED ON 0539 MODELS WITH FACTO

Pagina 10 - OPERATION

-EXAMPLE;FOR Rc TO Rh JUMPER. STRIP WIRE END LONG ENOUGH TO JOIN BOTH TERMINALS.FIG. 5-JUMPER "R^" AND "R„" TERMINALS FOR CO

Pagina 11 - 60-2246—4

PROTECTION AS REQUIRED.És^JUMPER FOR AUTO FAN IN ELECTRIC HEAT APPLICATIONS. IF JUMPER IS USED. MEASURE COMBINED “HEAT RELAY" AND "FAN RELAY

Pagina 12 - QUALITY IS KEY

Q539P/T87FAPOWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOADPROTECTION AS REQUIRED.M1029AMOLDED POST (2)VERTICAL PLUMP I LINEOPENING FOR THERMOSTAT

Modelos relacionados Q539H | Q539P | Q539C | Q539B | Q539J | Q539G |

Comentarios a estos manuales

Sin comentarios