Honeywell R841C-E Manual de usuario Pagina 1

Busca en linea o descarga Manual de usuario para Ampliaciones De Potencia Honeywell R841C-E. Honeywell R841C-E User's Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 7
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Honeywell
THE R841 ELECTRIC HEATING RELAY IS
USED WITH A 2-WIRE, 24V THERMOSTAT
TO PROVIDE CONTROL OF ELECTRIC
HEATING EQUIPMENT. IT IS A DIRECT-
FOLLOWING RELAY WHICH OPERATES
WITH EACH CYCLE OF THE THERMO-
STAT (4 TO 6 CYCLES PER HOUR).
R841C,D
models are used to control one
load.
R841E is used either with one thermostat
to control two loads simultaneously, or with
two thermostats to control two independent
loads.
R841C
and E models include an integral
transformer; R841 D model must be powered
from a remote 24V transformer.
R841C
and D models have a 1/2 inch male
conduit bushing.
The
R841C
,D
and E models are for instal-
lation on a wireway or J-box.
R841 E has a 1/2 inch male conduit bushing
and includes an enclosure with a low voltage
wiring compartment.
Special R841E with 10 second minimum
timing between stages is available.
Each relay switches up to a 5,000 watt load.
Spst MICRO SWITCH snap switches are
actuated by ambient-compensated
bimetal
strips.
Leadwires are provided for both line voltage
and low voltage connections.
Small size and silent operation allow instal-
lation in living area, utility room, or basement,
May be mounted in any convenient position.
R.E.
REV. 10-79 (.11)
Vista de pagina 0
1 2 3 4 5 6 7

Indice de contenidos

Pagina 1 - Honeywell

HoneywellTHE R841 ELECTRIC HEATING RELAY ISUSED WITH A 2-WIRE, 24V THERMOSTATTO PROVIDE CONTROL OF ELECTRICHEATING EQUIPMENT. IT IS A DIRECT-FOLLOWING

Pagina 2 - STANDARD MODELS

IMPORTANTTHE SPECIFICATIONS GIVEN IN THIS PUBLICATION DO NOT INCLUDE NORMAL MANUFACTURING TOLERANCES.THEREFORE, THIS UNIT MAY NOT MATCH THE LISTED SPE

Pagina 3 - IN in. [mm IN BRACKETS]

LEADWIRE LENGTH (NOMINAL):R841C,D–Line voltage–18 in. [457.2 mm].Low voltage–7-l/2 in. [ 190.5 mm].R841E–Line voltage–8 in. [203.2 mm].Low voltage–4 i

Pagina 4

WHEN INSTALLING THIS PRODUCT . . .1. Read these instructions carefully. Failure tofollow them could damage the product or cause ahazardous condition.2

Pagina 5

fAf ~~Ll (HOT) L22-WIRER841C 24 V\THERMOSTATBLUERED@ELEcTRIcoBLACK\llHEATERNO. 11eJRE515TANCEREDHEATER*TRANSFORMERr-%R841D RELAVACKREDWHITE.LOADR841D

Pagina 6 - THERMOSTAT

Q2-WIRE24 VTHERM05TA7A~6R120V —(L3 FOR 208, 240, OR 277 V]~ PowERs”PPLY.ADcl DISCONNECT MEAN5ANDOVERLOACI ,,0,.,TION AS REQUIREDA 5ETAD,”sTABLEHEAT AN

Pagina 7

The cycling pattern of the R841 is determined by thefrequency, the R841 switch contacts make approxi-thermostat(s). On a call for heat, the thermostat

Comentarios a estos manuales

Sin comentarios