6 Cable Installation and Removal Installation 1. Insert the cable’s modular connector into the socket on the imager. 2. Pull gently on the cable

Pagina 3 - Table of Contents

7 Interface Installation RS232 1. Turn off power to the host device. 2. Plug the interface cable’s modular connector into the socket on the imag

Pagina 4

8 Keyboard Wedge 1. Turn off power to the host device. 2. Plug the interface cable’s modular connector into the socket on the imager. 3. Disco

Pagina 5 - Introduction

9 RS485 1. Turn off power to the host device. 2. Plug the interface cable’s modular connector into the socket on the imager. 3. Connect the oth

Pagina 6 - Optional Accessories

10 USB 1. Turn off power to the host device. 2. Plug the interface cable’s modular connector into the socket on the imager. 3. Plug the USB end

Pagina 7 - Part # Description

11 • For information on configuring the MS7580 for USB Serial Emulation Mode or IBM OEM, refer to the USB section of the MetroSelect Single-Line

Pagina 9 - Maintenance

13 Mounting the MS7580 Components of Adapter Kit 46-00911 Item Item Description Qty. A Adapter Plate 1 B Locking Plate 1 C Base Cover 1 D M3

Pagina 10 - MS7580-124-EAS Model Note

14 Installation of Adapter Kit 46-00911 1. Remove the rubber feet on the bottom of the MS7580. 2. Attach the adapter plate to the bottom of the i

Pagina 11 - Interface Installation

15 5. Use the locking plate as a guide to drill three #39 pilot holes (A) in the mounting surface. Figure 13. Locking Plate (Not Drawn to Scale)

Pagina 12 - Keyboard Wedge

Disclaimer Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this document

Pagina 13 - Installation Note

16 Installation of Wall Mount Kit 46-00913 1. Drill two #39 pilot holes in the mounting surface. The pilot holes should be centered vertically 44

Pagina 14 - Installation Notes

17 Operation Modes of Operation The MS7580 supports two standard modes of operation for scanning bar codes, automatic activation and manual activat

Pagina 15

18 3. Press the button one time to activate linear targeting. 4. Align the linear targeting line over the desired bar code. Note: When scanni

Pagina 16

19 Audible Indicators The MS7580 provides audible feedback during operation. The audible feedback indicates the status of the imager. Eight setti

Pagina 17 - Mounting the MS7580

20 Visual Indicators The imager has blue and white LED indicators surrounding the button on the top of the imager. When the imager is on, the in

Pagina 18 - Figure 12

21 Failure Modes Long Razzberry Tone – During Power Up Failed to initialize or configure the imager. If the imager does not respond after reconfigu

Pagina 19 - Figure 15

22 Field of View Figure 20. Field of View

Pagina 20 - Figure 17

23 Depth of Field by Minimum Bar Code Element Width Minimum Bar Code Element Width 1D PDF QR+ Datamatrix A B C D F G mm .13 .19 .26 .33

Pagina 21 - Operation

24 IR Activation Range The MS7580 has a built in object detection sensor that instantly turns on the imager when an object is presented within the i

Pagina 22

25 Troubleshooting Guide The following troubleshooting guide is for reference purposes only. Contact a customer service representative or technica

Pagina 23 - Audible Indicators

iii Table of Contents Introduction Product Overview ... 1

Pagina 24 - Visual Indicators

26 Symptoms Possible Causes Solution The imager powers up, but does not beep when bar code is scanned. The beeper is disabled and no tone is sele

Pagina 25 - Failure Modes

27 Symptoms Possible Causes Solution The imager beeps at some bar codes and NOT for others of the same bar code symbology. The bar code may have

Pagina 26 - Field of View

28 Symptoms Possible Causes Solution The imager scans but the data is not correct. The imager and host may not be configured for the same interfa

Pagina 27 - 5.0 7.5 10.4 13 10 15

29 Design Specifications Operational Light Source: LED 645 nm ±7.5 nm Pulse Duration: Up to 600µs (Default) Maximum Output of the LED: Maximum 7

Pagina 28 - IR Activation Range

30 Mechanical Height (H): 150 mm (5.91") Width (W): 83 mm (3.27") Depth (D): 80 mm (3.15") Weight: 340 g ± 15 g (12 oz. ± 5 oz

Pagina 29 - Troubleshooting Guide

31 Applications and Protocols The model number on each imager includes the imager number and factory default communications protocol. Imager Versi

Pagina 31

33 Configuration and Upgrades Configuration Modes The MS7580 has three modes of configuration. • Bar Codes The MS7580 can be configured by scanni

Pagina 32 - Refer to the electrical

34 To upgrade the firmware in the MS7580: 1. Plug the imager into a serial communication port on the host system. 2. Start the MetroSet2 software

Pagina 33 - Design Specifications

35 MS7580-124-EAS Model MS7580-124-EAS models are equipped with an integrated antenna for Electronic Article Surveillance (EAS) system support. The

Pagina 34 - Environmental

iv Applications and Protocols ... 31 Configuration and Upgrades ...

Pagina 35 - Applications and Protocols

36 EAS System Connection The following information should be used in conjunction with the manufacturer’s documentation EAS system. Checkpoint® EAS

Pagina 36

37 Configuration for EAS Applications EAS support is disabled by default in the MS7580-124-EAS series. To enable EAS support the imager must be con

Pagina 37 - Configuration and Upgrades

38 3. Scan the desired EAS timeout length (applicable for regular mode only). The EAS timeout length specifies the maximum time that the area ima

Pagina 38

39 EAS Tag Deactivation Range Antenna Precaution The integrated EAS antenna is built into the stand/base of the imager. Do not enclose or rest the

Pagina 39 - MS7580-124-EAS Model

40 Figure 25. Expected Tag Deactivation Area (Top View)

Pagina 40 - EAS System Connection

41 Imager Pinouts–MS7580-124-EAS Figure 26. MS7580-124-EAS, 10-Pin Female Modular Socket RS232 USB Pin Function Pin Function 1 Signal/Powe

Pagina 41 - ³ 1 4 6 1 1 5

42 Cable Pinouts (Host End)‡ RS232, 12V VLink Cable MX-5S114-E-3 Pin Function Figure 28. 9-Pin Female, D-Type 1 Shield Ground 2 RS232 Receiv

Pagina 42 - Disable EAS Support

43 Imager and Cable Terminations Standard Imager Pinouts‡ Figure 31. Back/Connector View of the MS7580 RS232 Keyboard Wedge Pin Function Pin

Pagina 43 - EAS Tag Deactivation Range

44 Standard Cable Pinouts‡ (Host End) RS232, 12V VLink Cable 5S-5S000-3 Pin Function 9-Pin Female, D-Type 1 Shield Ground 2 RS232 Transmit

Pagina 44

45 Keyboard Wedge VLink Cable 5S-5S002-3 Pin Function 5-Pin DIN, Female 1 Keyboard Clock 2 Keyboard Data 3 No Connect 4 Power Ground 5 +5V

Pagina 45

1 Introduction Product Overview The MS7580 Genesis™ is a high performance presentation area-imaging bar code imager that utilizes CMOS imaging sens

Pagina 47 - Standard Imager Pinouts

47 Limited Warranty Honeywell International Inc. ("HII") warrants its products and optional accessories to be free from defects in materia

Pagina 48 - (Host End)

48 All provisions of this Limited Warranty are separate and severable, which means that if any provision is held invalid and unenforceable, such de

Pagina 49 - Keyboard Wedge Adapter Cable

49 Regulatory Compliance Safety ITE Equipment IEC 60950-1, EN 60950-1 LED Class 1 LED Product: IEC 60825-1:1993+A1+A2, EN 60825-1:1994+A1+A2 Cautio

Pagina 50

50 Wenn Sie dies tun, können Sie sich einer gefährlichen Licht emittierender Diodenstrahlung aussetzen. Der Einsatz optischer Geräte mit dieser Las

Pagina 51 - Limited Warranty

51 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful

Pagina 52

52 Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment

Pagina 53 - Regulatory Compliance

53 Index A AC ... 2, 7–11, 30 Accessories ... 2 Adapter ... 2, 13

Pagina 54 - Class A Devices

54 P Pass-Through ... 17 Pinouts ... 43, 44–45 Power ... 7–11, 30, 34 Po

Pagina 55 - Standard Europeo

55 Customer Support Technical Assistance If you need assistance installing or troubleshooting your device, please call your distributor or the nea

Pagina 56 - Class B Devices

2 Base Kit Components Part # Description MS7580-124 Genesis 7580 Presentation Area Imager 00-02544 MetroSelect® Single-Line Configuration G

Pagina 57

56 Product Service and Repair Honeywell International Inc. provides service for all its products through service centers throughout the world. To

Pagina 58

57 Patents For patent information, please refer to www.honeywellaidc.com/patents.

Pagina 61 - Patents

Honeywell Scanning and Mobility 9680 Old Bailes Road Fort Mill, SC 29707 www.honeywellaidc.com GEN-7580-UG Rev A 10/10

Pagina 62

3 Part # Description The MS7580 requires a cable designed for a 12VDC area imager. Do not attempt to use any cables other than the specified c

Pagina 63

4 MS7580 Components Item Item Description 1 Blue and White LED See Visual Indicators (on page 20) 2 Button Mode Select Button 3 Speaker See A

Pagina 64

5 Labels Each MS7580 has a label located near the top of the output window. This label provides the imager’s model number, date of manufacture, ser