3^1
CT53
WIRE AND MOUNT THERMOSTAT (continued)
Recheck for level position
ing, and firmly tighten both
mounting screws.
If installing CT50A, CT51 A,
or CT52A, make sure you
have the current (anticipator
setting) for your system. This is
the number you wrote in the box
in step 3. If you were unable to
find the current draw for step 3,
this information can be found
printed on the primary control at
the furnace. The primary control
is usually a gas valve, zone valve,
or a relay or burner control box
with the thermostat wires con
nected to it.
jncfi
OIL BURNER CONTROL
On the CT50A, CT51A, or
CT52A, set heat anticipator
indicator at rating printed on
primary control.
CHECKOUT
THE
THERMOSTAT
On the CT51A, the system
switch controls as follows:
HEAT—heating system only
operates.
. OFF—heating and cooling sys
tems are disconnected.
COOL—cooling system only
operates.
The fan switch controls as
follows:
AUTO—fan operates when
heating or cooling system,
operates.
ON—fan operates continu
ously.
NOTE: In the following instruction,
disregard heating or cooling
directions if not applicable to
your system.
Turn on power to the
heating/cooling system.
Observe system operation
for at least one cycle on
both heating and cooling. To
observe:
Place the system switch
at HEAT position and fan
switch at AUTO. More the temper
ature setting lever 10 F [5.6 C]
above room temperature. The
heating equipment should turn
on, A short warm-up period may
be required before the system
fan turns on.
Place system switch at
COOL position and move
temperature setting lever 10 F
[5.6 C[ below room temperature.
The cooling equiprnent should
turn on and the system fan should
turn on,
NOTE: Some systems have a time
delay that can prevent opera
tion up to 30 seconds.
Turn the fan switch to ON.
The system fan should turn
on, and operate continuously.
The system blower should con
tinue to operate at any system
switch or thermostat setting.
THERMOSTAT
SETTING
On CT51A, place the sys
tem and fan switches at
the desired settings for operation.
On all models, move the
temperature setting lever
to the desired temperature com
fort level.
(See ill
4 to hf
heat a|
Press the thermostat cover
firmly onto the mounting
Vista de pagina 4