/1\ POWER SUPPLY, PROVIDE DISCONNECT MEANS AND OVERLOAD PRO
TECTION AS REQUIRED,
/z\ CONNECT VALVE TO TERMINAL O FOR POWER ON COOLING OR TO
TERMINAL B FOR POWER ON HEATING,
A
TO SET ANTICIPATOR AT CORRECT RATING-MEASURE COMPRESSOR
RELAY CURRENT ON R WIRE WITH FAN SWITCH IN AUTO POSITION.
SET ANTICIPATOR AT 140 PERCENT OF CURRENT DRAW.
Fig. 14—Hookup showing a typicai single-stage heat pump control system.
THERMOSTAT
Fig, 15—Hookup showing a typical 2-stage heating/l-stage cooling heat pump control system.