Honeywell WT6500 Manual de usuario Pagina 23

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 46
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 22
16
SMARTBOX™ Controller for HONEYWELL™ Wind Turbine WT6500 Owner’s Manual - Rev14
SMARTBOX Installation
Battery Over-current Protection
TheNEC/CECrequiresthebatterycircuittobeprotectedwithadeviceratedfor125%
of the rating of the circuit. The DC-rated fuse or circuit breaker between the battery
and the SMARTBOX™ Controller must have a maximum size of 75A (the maximum
current rating of the SMARTBOX™ Controller).
SHOCK OR FIRE HAZARD
Over-current protection must be installed to protect the
SMARTBOX™ Controller from short circuits and to provide
a means of disconnecting it. Failure to follow this warning
may result in death, personal injury or property damage.
REVERSE POLARITY DAMAGE
BeforemakingthenalDCconnectionorclosingtheDC
breaker or disconnect, check cable polarity at both the
battery and the SMARTBOX™ Controller. Positive (+)
must be connected to positive (+). Negative(-) must be
connected to negative (-). Failure to follow this warning may
result in death, personal injury or property damage.
TURBINE SMARTBOX™ Controller
12V
12V
12V
12V
12V
12V
OPTIONAL
(2) #4 THWN-2 + #4 GND
1” CONDUIT
MAX DISTANCE 6 FEET.
Figure 2.8 Battery Circuit Diagram