6 INSTALLATION RS232, RS232 TTL, Light Pen or Laser Emulation 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink
7INSTALLATION RS485 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the MVC cable into the 10-pin socket on the IS3480. 3.
8 INSTALLATION Keyboard Wedge 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on th
9INSTALLATION Stand-Alone Keyboard 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socke
10INSTALLATION Low Speed USB (Integrated) 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the USB PowerLink cable into the 10-p
11INSTALLATION Notes for Laser Emulation IS3480-104 Only The IS3480-104 leaves the factory with the Laser Emulation Mode enabled. If the Reca
12SCANNER OPERATION Configurable Primary and Secondary Scan Pattern Modes There are two configurable scan pattern modes available with the IS348
13SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON CLICK MODE WITH CODEGATE ENABLED For illustration purposes the un
14SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON CLICK MODE WITH CODEGATE DISABLED For illustration purposes the u
15SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON HOLD MODE WITH CODEGATE ENABLED For illustration purposes the un
Disclaimer Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this document
16SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON HOLD MODE WITH CODEGATE DISABLED For illustration purposes the un
17SCANNER OPERATION Sweet Spot Mode The sweet spot mode is used to determine where the maximum read rate area or “sweet spot” is located for a
18SCANNER OPERATION Audible Indicators When the IS3480 is in operation, it can provide audible feedback. These sounds indicate the status of the
19SCANNER OPERATION Visual Indicators There are four LEDs located on the top of the IS3480. When the scanner is on, the flashing or constant il
20SCANNER OPERATION Failure Mode Indicators Flashing Blue and One Razzberry Tone This indicates that the scanner has experienced a laser subsys
21SCANNER OPERATION Depth of Field Specifications* Normal Scan Zone Specifications are based on a 0.33 mm (13 mil) bar code. Figure 9. Norma
22SCANNER OPERATION Depth of Field Specifications* Reduced Scan Zone Specifications are based on a 0.33 mm (13 mil) bar code. Figure 10. Reduc
23SCANNER OPERATION Depth of Field by Bar Code Element Width* Normal Scan Zone MINIMUM BAR CODE ELEMENT WIDTH A B C D E F mm .13 .15 .19 .
24SCANNER OPERATION Depth of Field by Bar Code Element Width* Reduced Scan Zone MINIMUM BAR CODE ELEMENT WIDTH A B C D E F mm .13 .15 .19
25SCANNER OPERATION IR Activation Range* QuantumE’s default power save mode† is Laser OFF. This power save mode turns the laser off after a con
ii TABLE OF CONTENTS Introduction Product Overview ... 1
26TROUBLESHOOTING GUIDE The following guide is for reference purposes only. Contact a Honeywell representative to preserve the limited warranty t
27TROUBLESHOOTING GUIDE Symptoms Possible Cause(s) Solution All Interfaces The unit scans a bar code, but locks up after the first scan (the whi
28TROUBLESHOOTING GUIDE Symptoms Possible Cause(s) Solution RS232 Only The unit powers up OK and scans OK but does not communicate properly to th
29 DESIGN SPECIFICATIONS IS3480 Operational Normal Depth of Field: 25 mm - 280 mm (1"- 11") 0.33 mm (13 mil) bar code Reduced Dept
30DESIGN SPECIFICATIONS IS3480 Mechanical Width: 63 mm (2.48") Depth: 50 mm (1.97") Height: 68 mm (2.68") Weight: 6 oz (170 g)
31APPLICATIONS AND PROTOCOLS The model number on each scanner includes the scanner number and factory default communications protocol. SCANNER V
32CONFIGURATION MODES The IS3480 Series scanner has three modes of configuration. • Bar Codes The IS3480 can be configured by scanning the bar co
33UPGRADING THE FIRMWARE The IS3480 is part of Honeywell's line of scanners with flash upgradeable firmware. The upgrade process requires, a
34DEFAULT SETTINGS - COMMUNICATION PARAMETERS Many functions of the scanner can be "configured" - that is enabled or disabled. The scan
35DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER DEFAULT USBRS232* OR RS232TTL LIGHT PEN RS485KBWLASER EMULATIONExpanded ID “]e0” *
iii TABLE OF CONTENTS IR Activation Range ... 25 Troubleshoot
36DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER DEFAULT USBRS232* OR RS232TTL LIGHT PEN RS485KBWLASER EMULATIONTransmit UPC-A Check Digi
37DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER DEFAULT USBRS232* OR RS232TTL LIGHT PEN RS485KBWLASER EMULATION Nixdorf ID L
38DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER DEFAULT USBRS232* OR RS232TTL LIGHT PENRS485KBWLASER EMULATIONSupplements are not Require
39SCANNER AND CABLE TERMINATIONS Scanner Pinout Connections The IS3480 scanner interfaces terminate to a 10-pin modular socket. The serial numbe
40SCANNER AND CABLE TERMINATIONS Figure 15. IS3480-104 RS232, RS232 TTL, or Laser Emulation Pin Function 1 Ground 2 RS232 Transmit Output 3 RS23
41SCANNER AND CABLE TERMINATIONS Figure 16. Figure 17. Zero Insertion Force Connector (ZIF), 6-pin Utility Connector Pin Function 1 Aux +5V:
42SCANNER AND CABLE TERMINATIONS Cable Connector Configurations (Host End) “Standard” PowerLink Cable 53-53000x-3 coiled or 59-59000x-3 straight
43SCANNER AND CABLE TERMINATIONS Cable Connector Configurations (Host End) Keyboard Wedge PowerLink Cable 59-59002x-3 Pin Function 5-Pin DIN,
44REGULATORY COMPLIANCE Safety ITE Equipment IEC 60950-1: 2005+A11, EN 60950-1:2006+A11 Laser Laser Class 1: IEC 60825-1:2007+A1+A2, EN 60825-1
45REGULATORY COMPLIANCE EMC Emissions FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity CISPR 24, EN 55024 NOTE: Immunity performance is not
1INTRODUCTION QuantumE ® is a miniature, omni-directional scanning engine with optional single-line scanning capability. The self-contained devi
46REGULATORY COMPLIANCE EMC Changes or modifications not expressly approved by the party responsible for compliance could void the user’s author
47LIMITED WARRANTY Honeywell International Inc. ("HII") warrants its products and optional accessories to be free from defects in mater
48LIMITED WARRANTY All provisions of this Limited Warranty are separate and severable, which means that if any provision is held invalid and unenf
49PATENTS For patent information, please refer to www.honeywellaidc.com/patents.
50INDEX A AC ... 2, 6–10 Accessories ... 2, 3 Adapter ...
51INDEX M Maintenance ... 3 Manual... 2, 18, 31 MetroSelect ...
52CUSTOMER SUPPORT Technical Assistance If you need assistance installing or troubleshooting your device, please call your distributor or the nea
53CUSTOMER SUPPORT Product Service and Repair Honeywell International Inc. provides service for all its products through service centers througho
54CUSTOMER SUPPORT Online Product Service and Repair Assistance You can also access product service and repair assistance online at www.honeywellaid
2 INTRODUCTION Scanner and Accessories BASIC KIT COMPONENTS Part No. Description IS3480 QuantumE Scanner 00-02026 IS3480 Installation and User’s
Honeywell Scanning & Mobility 9680 Old Bailes Road Fort Mill, SC 29707 www.honeywellaidc.com 00-02026 Rev H 11/10
3INTRODUCTION Scanner and Accessories OPTIONAL ACCESSORIES Part No. Description 59-59002x-3 Keyboard Wedge PowerLink cable 59-59020x-3 Stand
4 INTRODUCTION Scanner Components Figure 1a. Scanner Components ITEM NO. DESCRIPTION 1 Utility Connector Located Under Rubber Seal The rubber
5INTRODUCTION Caution and Serial Number Labels Figure 2. Caution To maintain compliance with applicable standards, all circuits connected t