MS2320 StratosH™ Scanner / Diva Scale Installation and User’s Guide
4 INTRODUCTION REPLACEMENT PARTS REPLACEMENT PARTS Part # Description Caution Window types (Diamonex and Sapphire) are not interchangeable due
5 INTRODUCTION GENERAL PRECAUTIONS The following list includes general precautions to remember when handling the StratosH. DO NOT TURN the un
6 INTRODUCTION MS2320 SCANNER/DIVA SCALE DESIGN SPECIFICATIONS Design Specifications Operational Light Source: VLD 650 nm Peak Laser Power: &l
7 BASE MODEL CHARACTERISTICS MS2320 Scanner/Diva Scale Components Figure 7. MS2320 Components ITEM NO. DESCRIPTION OF ITEM 1 Blue and Whit
8 BASE MODEL CHARACTERISTICS MS2320 Scanner/Diva Scale Dimensions Figure 8. MS2320 Dimensions Connector Panel Figure 9. MS2320 Connector
9 BASE MODEL CHARACTERISTICS MS2320 Scanner/Diva Scale Caution and Serial Number Labels Figure 10. MS2320 Label Locations (Top) and Examples (
10 INSTALLATION QUICK INSTALLATION OUTLINE The following is a quick preview of the steps required for first time installations. Each item is disc
11 INSTALLATION QUICK INSTALLATION OUTLINE POWER INSTALLATION The Power Supply (AC/DC) should be connected to an AC Outlet that is free of elec
12 INSTALLATION UNPACKING THE UNIT 1. Make sure the shipping box is top-side up before opening. 2. Remove the accessories box and check the b
13 INSTALLATION UNPACKING THE UNIT MS2320 Package Warning There is a protective film located on the topside platter surface, vertical scan windo
Disclaimer Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this document
14 INSTALLATION INSTALLING THE UNIT IN THE COUNTER MS2320 Mounting Diagram (Two Point Support) Figure 18. MS2320 Mounting Diagram, Two Point Supp
15 INSTALLATION INSTALLING THE UNIT IN THE COUNTER MS2320 Mounting Diagram (Three Point Support) Figure 19. MS2320 Mounting Diagram, Three Poin
16 INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) RS232 The following steps describe how to properly install the cables for an RS232 Stratos
17 INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) RS232 9. Turn on the host system. 10. Scan the Recall Defaults bar code. The Recall
18 INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) FULL SPEED USB The following steps describe how to properly install the cables for a Full S
19 INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) FULL SPEED USB 9. Turn on the host system. 10. Configure the StratosH to match the hos
20 INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) xxx* Specifies international connection. See page 3 for a complete listing of power s
21 INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) RS485 The following steps describe how to properly install the cables for an RS485 Stratos
22 INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) RS485 9. Turn on the host system. 10. Configure the StratosH to match the host system’s
23 INSTALLATION CABLE INSTALLATION (SECONDARY HONEYWELL SCANNER) The following steps describe how to properly install the cables between a secondar
ii TABLE OF CONTENTS INTRODUCTION Manual Scope ...
24 INSTALLATION CABLE INSTALLATION (SECONDARY HONEYWELL SCANNER) † See Aux power notes on page 23 See power source caution statement on page
25 INSTALLATION EAS DEACTIVATION SW1 and SW2 are the switch banks inside the Checkpoint device that set the deactivation range. The following is a
26 SCANNER OPERATION SCAN ZONE Figure 26. Checker-Side (13 mil) Figure 27. Horizontal Left/Right (13 mil) Specifications are subject to chan
27 SCANNER OPERATION SCAN ZONE Figure 28. Horizontal Direct (13 mil) Figure 29. Vertical Direct (13 mil) Specifications are subject to ch
28 SCANNER OPERATION IR ACTIVATION AREA (IR LED OUTPUT) The StratosH’s default power save mode† is Dual Action Power Save Mode #2 (see page 33). Th
29 Figure 31. LEDs SCANNER OPERATION INDICATOR DESCRIPTIONS Audible When in operation the StratosH provides audible feedback that indicates the
30 SCANNER OPERATION INDICATOR DESCRIPTIONS Visual Steady White and Blue After a successful scan, the scanner transmits the data to the host devi
31 SCANNER OPERATION INDICATOR DESCRIPTIONS Diagnostic Indicator Display There is a two-digit error code display located under the platter near t
32 SCANNER OPERATION INDICATOR DESCRIPTIONS Diagnostic Indicator Display ERROR CODE DESCRIPTION 11 SWITCH ERROR – The switch used for volume sele
33 SCANNER OPERATION POWER SAVE MODES The StratosH has five configurable power save modes. Refer to the MetroSelect Configuration Guide (PN 00-02
iii TABLE OF CONTENTS Cable Installation (Secondary Honeywell Scanner) ...
34 SCANNER OPERATION BEEPER OPTIONS AND BUTTON FUNCTIONS Changing the Beeper Tone Beeper tones may be configured incrementally using the following
35 SCANNER OPERATION STARTUP When the scanner first receives power the white LED will flash, the blue LED will turn on and the scanner will beep o
36 SCALE OPERATION SCALE ZEROING After the unit has been officially calibrated (see page 37) the scale can be re-zeroed by pressing the scale zeroi
37 SCALE OPERATION CALIBRATION The scanner/scale must be calibrated if: • it is a first time installation • the scale cannot be re-zeroed • th
38 SCALE OPERATION CALIBRATION Priming the Scale for Calibration Prime the scale before starting either method of calibration. Calibrate the sca
39 SCALE OPERATION CALIBRATION Scale Calibration Procedure (lbs. or kg) with Remote Display* 1. Temporarily remove the platter and place it in a
40 SCALE OPERATION CALIBRATION Scale Calibration Procedure (lbs. or kg) with Remote Display* 4. Reinstall the platter onto the scanner/scale.
41 SCALE OPERATION CALIBRATION Scale Calibration Procedure (lbs. or kg) with Remote Display * 7. Go to Group 2 Step 6 (Calibration) of the Servi
42 SCALE OPERATION CALIBRATION Bar Code Calibration Procedure without Remote Display* The following calibration procedure can be used when the
43 ³ 9 9 6 0 4 2SCALE OPERATION CALIBRATION Bar Code Calibration Procedure without Remote Display* 4. Reinstall the platter onto the scanner/sca
iv TABLE OF CONTENTS TROUBLESHOOTING Troubleshooting Symptom / Solution Chart ...
44 ³ 9 9 6 0 4 4SCALE OPERATION CALIBRATION Bar Code Calibration Procedure without Remote Display* Unit Calibration (Kilograms) For Pound weight
45 SCALE OPERATION CALIBRATION Bar Code Calibration Procedure without Remote Display* 8. Place a FULL Load on the center of the scale platter.
46 SCALE OPERATION CALIBRATION VERIFICATION U.S. Pounds (lbs.) The following tests verify if the scale's Calibration is accurate. For Kilogr
47 SCALE OPERATION CALIBRATION VERIFICATION Kilograms (kg) The following tests verify if the scale's Calibration is accurate. For US Poun
48 SCALE OPERATION SECURITY SEAL INSTALLATION The certification of the weighing mechanism of the scale version of this scanner is subject to feder
49 SCALE OPERATION SECURITY SEAL INSTALLATION Wire Security Seal (Seal Conversion Kit PN 46-00359)* 1. Temporarily remove the platter and plac
50 MAINTENANCE PLATTER / HORIZONTAL SCAN WINDOW REPLACEMENT Figure 61. Platter/Horizontal Scan Window Replacement* * See replacement parts
51 MAINTENANCE VERTICAL SCAN WINDOW REPLACEMENT (PN 46-46889) Figure 62. Vertical Scan Window Replacement DAILY MAINTENANCE Smudges and
52 TROUBLESHOOTING The following guide is for reference purposes only. Contact a customer service representative to preserve the limited warranty t
53 TROUBLESHOOTING Symptom Possible Cause(s) Solution All Interfaces Scanner beeps at some bar codes and NOT for others of the same bar code symb
54 SCANNER AND CABLE TERMINATIONS SCANNER PINOUT CONNECTIONS The StratosH scanner terminates to 10-pin modular jacks located on the bottom of the
55 SCANNER AND CABLE TERMINATIONS SCANNER PINOUT CONNECTIONS Figure 64. Scale Data (Dual Cable Applications) and Scale Display Connector Layout
56 SCANNER AND CABLE TERMINATIONS CABLE CONNECTOR CONFIGURATIONS The following cables are examples of some of the standard cables that may be ship
57 SCANNER AND CABLE TERMINATIONS CABLE CONNECTOR CONFIGURATIONS Aux Port Configuration Cable*, PN 57-57008x-N-3 Pin Function** 9-Pin D-Type Con
58 REGULATORY COMPLIANCE SAFETY ITE Equipment IEC 60950-1 Second Edition EN 60950-1 Second Edition Laser Laser Class 1: IEC 60825-1: Second Edit
59 REGULATORY COMPLIANCE EMC Emissions FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity CISPR 24, EN 55024 Note: Immunity performance is not
60 REGULATORY COMPLIANCE EMC Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authori
61 LIMITED WARRANTY Honeywell International Inc. ("HII") warrants its products and optional accessories to be free from defects in materi
62 INDEX A AC ... see power application ...
63 INDEX R razzberry tone ... 29, 30 regulatory compliance ...
1 INTRODUCTION MANUAL SCOPE This guide provides information on the installation, setup and operation of Honeywell’s StratosH™ MS2320 scanner/Diva
64 CUSTOMER SUPPORT TECHNICAL ASSISTANCE If you need assistance installing or troubleshooting your device, please contact us by using one of the me
Honeywell Scanning & Mobility 9680 Old Bailes Road Fort Mill, SC 29707 www.honeywellaidc.com 00-02271 Rev H 8/12
2 INTRODUCTION BASE KIT COMPONENTS BASE KIT COMPONENTS Part # Description MS2320-xxKz StratosH Scanner / Diva Scale xx 14 RS232 Interface 21
3 INTRODUCTION OPTIONAL ACCESSORIES Part # Description AC to DC Power Transformer - Regulated Output: +5V @ 4A +12V @ 1.5A 46-46812 120V U
Comentarios a estos manuales